Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 272
Filter
1.
Arq. bras. oftalmol ; 87(3): e2022, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1520214

ABSTRACT

ABSTRACT Purpose: The possible variability in diagnostic test results is a statistical feature of dry eye disease patients. The clinician should consider tear film variations over time since the timing of tear film measurements is important for proper diagnosis. The purpose of the present study was to analyze the inter-week variation of osmolarity measurement in healthy and dry eye disease participants. Methods: Based on the Dry Eye Workshop II (DEWS-II) diagnostic methodology report criteria, a battery of tests (Ocular Surface Disease Index [OSDI] questionnaire, breakup time, and corneal staining) was administered to rule out the presence of dry eye disease. A total of 40 qualified volunteers were recruited into two groups: with only 20 healthy and 20 dry eye disease participants. The inter-week variation of osmolarity in the two groups was measured using a TearLab osmometer in two sessions one-week apart. The differences between the results were calculated. Results: There were no significant differences in osmolarity between the two sessions for either the healthy (paired t-test; p=0.085) or dry eye disease (paired t-test; p=0.093) participants. Moreover, there was no significant correlation between the means and differences in either session on healthy (Pearson correlation: r=0.020; p=0.935) or dry eye disease (Pearson correlation: r=-0.022; p=0.928) participants. In session 1, there was a significant difference in osmolarity values between groups (unpaired t-test; p=0.001), but no difference was found in session 2 (unpaired t-test; p=0.292). Conclusions: The present study discovered no inter-week variation in the tear film osmolarity of healthy and dry eye disease participants classified based on the DEWS-II criteria.


RESUMO Objetivo: A possível variabilidade nos resultados de testes diagnósticos é uma característica estatística dos pacientes com síndrome do olho seco. O médico deve considerar as variações do filme lacrimal ao longo do tempo, pois o momento em que o filme lacrimal é medido pode ser crítico para o diagnóstico adequado. O objetivo deste estudo foi analisar a variação semanal da osmolaridade do filme lacrimal em participantes saudáveis e em outros com síndrome do olho seco. Métodos: Com base nos critérios da metodologia de diagnóstico do relatório da Dry Eye Workshop II (DEWSII), foi aplicada uma bateria de testes (questionário do índice de doença da superfície ocular [OSDI], tempo de ruptura do filme lacrimal e coloração da córnea) para descartar a presença de síndrome do olho seco. Um total de 40 voluntários qualificados foi recrutado e distribuído em dois grupos de 20 participantes saudáveis e 20 participantes com síndrome do olho seco. A variação da osmolaridade entre semanas foi medida com um osmômetro TearLab em duas sessões com uma semana de intervalo nos dois grupos. As diferenças entre os resultados foram então calculadas. Resultados: Não foram encontradas diferenças significativas na osmolaridade entre as medidas obtidas nas duas sessões, nem no grupo de participantes saudáveis (teste de t pareado; p=0,085), nem no de participantes com síndrome do olho seco (teste de t pareado; p=0,093). Não foi detectada nenhuma correlação significativa entre as médias e diferenças entre as duas sessões entre participantes saudáveis (correlação de Pearson: r=0,020, p=0,935) e aqueles com síndrome do olho seco (correlação Pearson: r=-0,022, p=0,928). Foi encontrada uma diferença significativa nos valores de osmolaridade entre os dois grupos na primeira sessão (teste de t não pareado; p=0,001), mas nenhuma diferença foi encontrada na segunda sessão (teste de t não pareado; p=0,292). Conclusões: O presente estudo não encontrou variação entre semanas consecutivas na osmolaridade do filme lacrimal em participantes saudáveis e com síndrome do olho seco, classificados com base nos critérios do DEWSII.

2.
Arq. bras. oftalmol ; 87(3): e2022, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1520217

ABSTRACT

ABSTRACT Purpose: Dry eye disease is a multifactorial disease that is very common in clinical ophthalmic practice. The use of validated dry eye questionnaires makes it possible to screen this disease in the general population and assess the prevalence of symptoms and frequency of diagnosis, allowing early and appropriate treatment for this condition. The 5-Item Dry Eye Questionnaire (DEQ-5) is a tool that is used to assess the frequency and intensity of ocular discomfort and dryness and the frequency of tearing, which has already been validated in English and Spanish, but not in Portuguese. The aim of this study is to translate and validate the DEQ-5 to Portuguese. Methods: The DEQ-5 was used, consisting of five simple and direct questions: two questions for ocular discomfort, two for ocular dryness, and one for tearing. The initial translation of the English version of the questionnaire into Portuguese was conducted by two Portuguese native-speaking translators, followed by an evaluation and compilation of a single version by an interdisciplinary committee of the translated versions. Furthermore, this version was translated back into English by two individuals whose first language was English, followed by the evaluation and comparison with the original version in English by the same interdisciplinary committee. Afterwards, the final version of the questionnaire was administered to 31 volunteers at two different times. Results: The interobserver reliability of the five questions ranged from 0.584-0.813, and the Pearson correlation from 0.755-0.935, with a p-value of <0.0001. Internal consistency was α=0.887. All questions had moderate to high agreement. Conclusions: The statistical analysis of the collected data found excellent concordance rates (moderate to high for all analyzed questions), allowing the use of the Portuguese version of DEQ-5 in research as a screening test for dry eye disease and tool used to monitor the symptoms.


RESUMO Ojetivos: O olho seco é uma doença multifatorial, muito comum na prática clínica oftalmológica. A utilização de questionários validados de sintomas de olho seco permite rastrear de maneira mais objetiva essa doença na população geral, avaliar a prevalência dos sintomas e frequência de diagnóstico, permitindo o tratamento precoce e adequado dessa condição. O 5-Item Dry Eye Questionnaire (DEQ-5) é um questionário em inglês que avalia a frequência e a intensidade do desconforto e ressecamento ocular e a frequência do lacrimejamento, já validado no inglês e espanhol, porém não no português até o presente momento. O objetivo deste estudo foi traduzir e validar o questionário DEQ-5 para a língua portuguesa. Métodos: Foi utilizado o questionário DEQ-5, composto por 5 perguntas simples e diretas - 2 relacionadas ao desconforto ocular, 2 ao ressecamento ocular e 1 ao lacrimejamento. Foi realizada a tradução inicial da versão em inglês para o português por dois tradutores de língua materna portuguesa, seguido de uma avaliação e compilação de uma versão única por um comitê interdisciplinar das versões traduzidas. Em seguida, tal versão foi traduzida de volta para o inglês por 2 indivíduos que possuíam o inglês como primeira língua, seguido de avaliação e comparação com a versão original em língua inglesa pelo mesmo comitê interdisciplinar. Após, a versão final do questionário foi aplicada em 31 voluntários em dois momentos differentes. Resultados: A confiabilidade interobservador das 5 perguntas variou de 0,584-0,813 e a correlação de Pearson de 0.755-0.935, sendo o p-valor <0,0001 em todas elas. A consistência interna foi α=0,887. Todas as perguntas apresentaram concordância de moderada a alta. Conclusões: A análise estatística dos dados coletados encontrou ótimos índices de concordância - moderada a alta para todas as questões analisadas -, permitindo o uso do DEQ-5 na língua portuguesa em pesquisas e também como forma de triagem para doença de olho seco e acompanhamento dos sintomas.

3.
Arq. bras. oftalmol ; 87(4): e2022, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1520232

ABSTRACT

ABSTRACT Purpose: To compare the differences between the apparent and actual chord μ. Methods: In this prospective, comparative, non-randomized, and non-interventional study, imaging examinations using Pentacam and the HD Analyzer were performed in the same room under the same scotopic conditions. The inclusion criteria were patients aged 21-71 years, able to provide informed consent, myopia up to 4D, and anterior topographic astigmatism up to 1D. Patients using contact lenses, those with previous eye diseases or surgeries, corneal opacities, corneal tomographic changes, or suspected keratoconus were excluded. Results: Altogether, 116 eyes of 58 patients were analyzed. The patients' mean age was 30.69 (±7.85) years. In the correlation analyses, Pearson's correlation coefficient of 0.647 indicates a moderate positive linear relationship between apparent and actual chord μ. The mean actual and apparent chord μ were 226.21 ± 128.53 and 278.66 ± 123.90 μm, respectively, with a mean difference of 52.45 μm (p=0.01). The analysis of mean pupillary diameter resulted in 5.76 mm using the HD Analyzer and 3.31 mm using the Pentacam. Conclusions: We found a correlation between the two measurement devices, and even though we found considerable differences, both can be used in daily practice. Given their differences, we should respect their peculiarities as well.


RESUMO Objetivo: Comparar as diferenças entre a chord aparente μ e o chord real μ. Métodos: Estudo prospectivo, comparativo, não randomizado e não intervencionista. Os exames de imagem (Pentacam e HD Analyzer) foram realizados na mesma sala e nas mesmas condições escotópicas. Os critérios de inclusão foram idade de 21 a 71 anos; compreensão do termo de consentimento; miopia até 4D e astigmatismo topográfico anterior até 1D. Os critérios de exclusão foram usuários de lentes de contato; pacientes com doenças oculares prévias ou cirurgias; opacidades da córnea; a presença de alterações tomográficas da córnea ou suspeita de ceratocone. Resultados: Em nosso estudo foram analisados 116 olhos de 58 pacientes. A média de idade foi de 30,69 anos (± 7,85). Análises de correlação foram desenvolvidas e o coeficiente de correlação de Pearson (0,647) indica uma relação linear positiva moderada entre as variáveis. A média do chord μ real foi 226,21 ± 128,53 μm e a média do chord μ média foi 278,66 ± 123,90 μm, com diferença média de 52,45 μm (p=0,01). A análise do diâmetro pupilar médio apresentou: 5,76mm no HD Analyzer e 3,31mm no Pentacam. Conclusões: Entendemos a existência de uma diferença significativa entre os métodos e assim a medida de ambos os dispositivos com base em princípios diferentes devemos respeitar suas peculiaridades. Como encontramos correlação entre as duas medidas, acreditamos que ambas podem ser utilizadas na prática diária.

4.
Biomédica (Bogotá) ; 43(Supl. 1)ago. 2023.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1533891

ABSTRACT

Introducción. La paracoccidioidomicosis es una micosis sistémica y endémica en Latinoamérica. El cambio climático y el movimiento migratorio del huésped enfatizan la necesidad de optimizar el diagnóstico de esta infección. Objetivo. Evaluar la implementación de la detección de ADN de Paracoccidioides spp. al diagnóstico micológico de pacientes con sospecha de paracoccidioidomicosis. Materiales y métodos. Estudio retrospectivo con datos de laboratorio de pacientes con sospecha de paracoccidioidomicosis en un hospital de área no endémica. Resultados. Se analizaron los resultados de las muestras de 19 pacientes con sospecha clínica de paracoccidioidomicosis. El 90 % de los pacientes había nacido o visitado un área endémica de esta micosis en Latinoamérica. En 14 pacientes varones adultos se confirmó paracoccidioidomicosis por diagnóstico convencional. El examen directo fue positivo en 12 pacientes con enfermedad comprobada y en 4 de ellos se obtuvo crecimiento del hongo. Se detectaron anticuerpos contra Paracoccidioides spp. en ocho pacientes con la enfermedad. Se realizó PCR anidada con muestras de 14 pacientes para detectar ADN de Paracoccidioides spp. En 9 de los 10 pacientes con diagnóstico convencional de paracoccidioidomicosis se obtuvo una prueba de PCR positiva. Conclusiones. La implementación de técnicas moleculares para detectar ADN de Paracoccidioides spp. complementa el diagnóstico convencional de paracoccidioidomicosis y permite instaurar el tratamiento antifúngico, sobre todo en los casos clínicos donde no se observa la presencia del hongo en las muestras clínicas. La migración actual de poblaciones humanas dificulta el diagnóstico de paracoccidioidiomicosis y otras infecciones endémicas, por lo que se requiere optimizar el diagnostico micológico en los laboratorios clínicos para tratar pacientes con este tipo micosis desatendida.


Introduction. Paracoccidioidomycosis is a systemic mycosis endemic in Latin America. Climate change and host migration emphasize the need to optimize this infection diagnosis. Objective. To evaluate the implementation of Paracoccidioides spp. DNA detection in the mycological diagnosis of patients with suspected paracoccidioidomycosis. Materials and methods. It is a retrospective study with laboratory data from patients with clinical suspicion of paracoccidioidomycosis, who consulted a university hospital from a non-endemic area. Results. We analyzed the laboratory results of samples from 19 patients with suspected paracoccidioidomycosis. Seventeen out of 19 patients were born in or had visited an endemic area in Latin America. Fourteen adult male patients were confirmed to have paracoccidioidomycosis by conventional diagnosis: the direct examination was positive in 12 samples while fungal growth was found only in 4. Anti-Paracoccidioides spp. antibodies were detected in 10 patients, 8 of them with proven paracoccidioidomycosis. Nested PCR for Paracoccidioides spp. detection was performed on clinical samples from 14 patients, and positive results were obtained for 9 out of 10 patients with the conventional diagnosis of paracoccidioidomycosis. Conclusions. The incorporation of molecular techniques to detect Paracoccidioides spp. DNA complements the conventional diagnosis of paracoccidioidomycosis. This tool allows the prescription of antifungal treatment in those cases where the fungus is not observed in the clinical samples. Current human migrations difficult the mycological diagnosis of paracoccidioidomycosis and other fungal infections. For this reason, it is necessary to improve mycological diagnosis in clinical laboratories to adequately treat patients with this neglected mycosis.

5.
Pediatr. (Asunción) ; 50(2)ago. 2023.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1507000

ABSTRACT

Introducción: La miocardiopatía hipertrófica (MCH) constituye una enfermedad compleja y variable en cuanto a morfología, fisiopatología, pronóstico y sobrevida. Se caracteriza por una hipertrofia del ventrículo izquierdo, aunque en ocasiones puede ser biventricular o ventricular derecha aislada. En la edad pediátrica predominan las causas no sarcoméricas. La ecocardiografía es el método diagnóstico más utilizado para caracterizar la morfología y repercusión hemodinámica, sin embargo, la resonancia magnética cardíaca (RMC) es de elección por aportar mayores ventajas morfológicas y funcionales. Las pruebas genéticas son de gran importancia en la determinación del diagnóstico etiológico, manejo terapéutico y pronóstico. El tratamiento tiene como objetivo principal mejorar la capacidad funcional y aliviar los síntomas. Los betabloqueantes no vasodilatadores son considerados de primera líneay en algunos casos se puede recurrir a terapias avanzadas como disopiramida o terapia de reducción septal (TRS), uso del cardiodesfibrilador implantable (CDI), y en ocasiones se debe considerar trasplante cardiaco en pacientes con síntomas refractarios al tratamiento médico y en MCH del tipo obstructivo. Materiales y métodos: Estudio observacional, descriptivo, corte transversal. Resultados: Se estudiaron 12 pacientes, desde enero de 2020 a diciembre de 2022, con edades comprendidas desde 5 meses hasta 16 años, diagnosticados con MCH de presentación clínica variable y de distintas etiologías. Conclusión: La MCH de causas no sarcoméricas como los síndromes malformativos y errores innatos del metabolismo son las que tienen peor pronóstico y sobrevida. La finalidad de detectar precozmente la MCH es el inicio temprano de la terapia específica, para así retrasar el compromiso cardiovascular y mejorar la sobrevida.


Introduction: Hypertrophic cardiomyopathy (HCM) is a complex and variable disease in terms of morphology, pathophysiology, prognosis and survival. It is characterized by left ventricular hypertrophy, although it can sometimes be biventricular or isolated right ventricular. In the pediatric population, non-sarcomeric causes predominate. Echocardiography is the most widely used diagnostic method to characterize morphology and hemodynamic repercussions; however, cardiac magnetic resonance imaging (CMR) is preferred because it provides greater morphological and functional advantages. Genetic tests are of great importance in determining the etiological diagnosis, therapeutic management and prognosis. The main objective of the treatment is to improve functional capacity and alleviate symptoms. Non-vasodilator beta-blockers are considered first-line treatment and in some cases advanced therapies such as disopyramide or septal reduction therapy (SRT), use of implantable cardioverter-defibrillator (ICD) can be used; heart transplantation should be considered in patients with symptoms refractory to medical treatment and in HCM of the obstructive type. Materials and methods: This was an observational, descriptive, cross-sectional study. Results: 12 patients were studied, from January 2020 to December 2022, with ages ranging from 5 months to 16 years, diagnosed with HCM of variable clinical presentation and of different etiologies. Conclusion: HCM from non-sarcomeric causes such as malformation syndromes and inborn errors of metabolism have the worst prognosis and survival. The purpose of early detection of HCM is the early initiation of specific therapy, in order to delay cardiovascular compromise and improve survival.

6.
Arq. bras. oftalmol ; 86(4): 388-396, July-Sep. 2023. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1447367

ABSTRACT

ABSTRACT Cycloplegia is crucial for reliable pediatric ophthalmology examinations. This document provides a re­commendation for pediatric cycloplegia and mydriasis for Brazilian ophthalmologists. This article was developed based on literature reviews; the clinical experience of Brazilian specialists, as obtained through questionnaires; and the consensus of the Expert Committee of the Brazilian Pediatric Ophthalmology Society. According to the best evidence and formulations available in Brazil, this committee recommends the use of one drop of 1% cyclopentolate plus one drop of 1% tropicamide in children older than 6 months and two drops of 1% tropicamide 0-5 minutes apart for those younger than 6 months. Mydriasis may be increased by a single drop of 2.5% phenylephrine. For retinopathy of prematurity screening, the recommendation is 0.5% or 1% tropicamide, administered two or three times, 5 minutes apart, and 2.5% phenylephrine, used preferably once. In all scenarios, we recommend the use of a prior drop of 0.5% proxymetacaine.


RESUMO A cicloplegia é crucial para um exame oftalmológico pediátrico acurado. Este documento visa a fornecer uma recomendação para cicloplegia e midríase pediátrica para oftalmologistas brasileiros. Foi desenvolvido com base em revisão literária, na experiência clínica de especialistas brasileiros, por meio de questionários, e no consenso do comitê de especialistas da Sociedade Brasileira de Oftalmologia Pediátrica (SBOP). De acordo com as melhores evidências, este comitê recomenda o uso de uma gota de ciclopentolato 1%, mais uma gota de tropicamida 1% em crianças maiores de 6 meses e duas gotas de tropicamida 1% com intervalo de 0-5 minutos para menores de 6 meses. A midríase pode ser potencializada por uma gota de fenilefrina 2,5%. Para o rastreamento da retinopatia da prematuridade, a recomendação é tropicamida 0,5 ou 1%, duas ou três vezes, com 5 minutos de intervalo, e 2,5% de fenilefrina, preferencialmente uma vez. O uso prévio de proxymetacaína 0,5% é sempre recomendado.

7.
Arq. bras. oftalmol ; 86(4): 365-371, July-Sep. 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1447370

ABSTRACT

ABSTRACT Purpose: To compare ocular surface parameters in rosacea patients with those of controls. Methods: Ninety-three participants took part in this cross-sectional, observational, non-interventional study. These consisted of a rosacea group (n=40) and a control group (n=53). We compared objective parameters of the ocular surface, including conjunctival hyperemia, tear film stability and volume, meibomian gland dysfunction, dry eye disease, and ocular surface staining, between the two groups. Results: In the rosacea group, 69.23% were female. The mean age was 47.34 ± 12.62 years old. No statistically significant differences between groups were found in visual acuity (p=0.987), tear film parameters (tear meniscus height (p=0.338), noninvasive tear film rupture time (p=0.228), invasive rupture time (p=0.471), Schirmer's test scores (p=0.244), conjunctival hyperemia (p=0.106), and fluorescein staining (p=0.489). Significant differences were found in meibography evaluations (p=0.026), mucous layer integrity (p=0.015), and ocular surface symptoms (p<0.0001). Rosacea patients also showed important eyelid differences in glandular expressibility (p<0.001), glandular secretion pattern (p<0.001), and telangiectasia (p<0.001) compared to controls. Conclusion: Meibomian gland dysfunction is frequently associated with dermatological conditions. It can be observed in morphological findings from meibography as well as lipid secretion impairment, leading to evaporative dry eye, ocular surface dysfunction, and inflammation.


RESUMO Objetivo: Avaliar as alterações da superfície ocular em pacientes com Rosácea, e comparar com grupo controle. Métodos: Noventa e três indivíduos foram selecionados para este estudo transversal, observacional e não intervencionista, dividido em dois grupos: rosácea (n=40) e controles (n=53). Foram avaliados parâmetros objetivos da superfície ocular (hiperemia conjuntival, estabilidade e volume do filme lacrimal, disfunção da glândula meibomiana, doença do olho seco, coloração da superfície ocular) e comparado indivíduos saudáveis com pacientes com rosácea. Resultados: 69,23% dos indivíduos com rosácea eram mulheres, com média de idade de 47,34 ± 12,62 anos. Em comparação com controles pareados, não foram evidenciadas diferenças estatisticamente significativas em relação à acuidade visual (p=0,987) e parâmetros do filme lacrimal (altura do menisco lacrimal (p=0,338), tempo de ruptura do filme lacrimal não invasivo (p=0,228), tempo invasivo de ruptura (p=0,471) e teste de Schirmer (p=0,244), bem como hiperemia conjuntival (p=0,106) e coloração com fluoresceína (p=0,489). Associação significativa foi encontrada na avaliação da meibografia (p=0,026), integridade da camada mucosa (p=0,015) e sintomas de superfície ocular (p<0,0001). Pacientes com rosácea também apresentaram alterações importantes na borda palpebral: expressibilidade glandular (p<0,001), padrão de secreção glandular (p<0,001) e telangiectasia (p<0,001). Conclusão: A disfunção da glândula de Meibômio está frequentemente associada a condições dermatológicas e é caracterizada por achados morfológicos na meibografia, bem como comprometimento da secreção lipídica que leva ao olho seco evaporativo e alterações da superfície ocular e inflamação.

8.
Audiol., Commun. res ; 28: e274128, 2023. tab, graf
Article in Portuguese | LILACS | ID: biblio-1439469

ABSTRACT

RESUMO Vários estudos mostram a importância da avaliação quantitativa na patência nasal e do estado funcional das vias aéreas superiores para fornecer informações clínicas e diagnósticas em indivíduos respiradores orais, as quais são de grande interesse para a fonoaudiologia. O objetivo deste estudo foi avaliar o efeito da irrigação de solução salina nasal nas vias aéreas superiores através da aeração nasal e rinomanometria anterior ativa em crianças respiradoras orais. Estudo de série de oito casos, realizado em crianças com idades entre 7 e 10 anos, com diagnóstico clínico otorrinolaringológico de respiração oral. O estudo consistiu em três etapas: avaliação inicial; intervenção e avaliação final. Foram aplicados os questionários do Índice de Identificação dos Sinais e Sintomas da Respiração Oral e qualidade de vida específica para doenças em pacientes pediátricos com queixas sinonasais. Realizaram-se as avaliações da aeração nasal e o exame da rinomanometria anterior ativa. A intervenção foi realizada por meio da irrigação de solução salina nasal com 10 ml. Em seguida, os pacientes foram reavaliados pela avaliação da aeração nasal e rinomanometria, para comparar os resultados. Em relação à avaliação da aeração nasal e rinomanometria, das 16 medidas comparativas entre pré e pós-irrigação nasal, constataram-se mudanças significativas na aeração nasal e na resistência nasal. A irrigação nasal resultou em melhora nas medidas da aeração nasal, enquanto para o fluxo nasal da rinomanometria, as medidas permaneceram inalteradas entre pré e pós-irrigação nasal.


ABSTRACT Several studies have shown the importance of quantitative assessment in nasal patency and functional status of the upper airways to provide clinical and diagnostic information in oral breather individuals, which are of great interest to speech therapy. The aim of the study was to evaluate the effect of nasal saline solution irrigation on the upper airways through nasal aeration and active anterior rhinomanometry in oral breathing children. This was an eight case series study, carried out in children aged 7 to 10 years with an otorhinolaryngological clinical diagnosis of mouth breathing. The study consisted of three stages: (I) initial evaluation; (II) intervention; and (III) final evaluation. The questionnaires of the Index for the Identification of Oral Breathing Signs and Symptoms and disease-specific quality of life in pediatric patients with sinonasal complaints were applied, nasal aeration assessments and the anterior active rhinomanometry exam were carried out. The intervention was performed by irrigating nasal saline solution with 10ml. Afterwards, they were re-evaluated by nasal aeration evaluation and rhinomanometry to compare the results. Regarding nasal aeration and rhinomanometry evaluation, from the 16 comparative measurements between pre and post nasal irrigation, we obtained significant changes in nasal aeration and nasal resistance. Nasal irrigation resulted in improvement in nasal aeration measurements while nasal flow measurements from rhinomanometry remained unchanged considering pre and post nasal irrigation.


Subject(s)
Humans , Male , Female , Child , Airway Resistance , Rhinomanometry/methods , Saline Solution/therapeutic use , Mouth Breathing/diagnosis , Nasal Obstruction
9.
Article in Spanish | LILACS, BIMENA | ID: biblio-1551676

ABSTRACT

Introducción: la muerte súbita se trata de un evento fatal e imprevisible. Realizada la autopsia y estudios complementarios, en ausencia de otros hallazgos que expliquen la causa de muerte, se clasifica como muerte súbita inexplicada. Siendo recomendable en estos casos realizar análisis genéticos, especialmente con metodologías de secuenciación de siguiente generación, las que permiten explicar un porcentaje importante de estos casos. Objetivo: analizar las publicaciones más relevantes sobre secuenciación de siguiente generación, aplicada a la autopsia molecular, para determinar aquellas muertes súbitas inexplicables relacionadas a cardiomiopatías y canalopatías. Metodología: se realizó la búsqueda en PubMed del Instituto Nacional de Salud usando palabras clave en inglés y español: NGS, muerte súbita, autopsia molecular y sus combinaciones. Además, se realizaron búsquedas en OMIN y ClinVar relacionada a las diferentes afecciones cardiacas relacionadas a muerte súbita. Los criterios de inclusión: artículos completos en español e inglés de libre acceso, con antigüedad máxima de diez años, realizados en cualquier área geográfica y que trataran sobre la temática. Resultados: para secuenciación de siguiente generación, muerte súbita se encontraron más de 22000 y 65000 publicaciones, respectivamente. En cambio, al combinar las palabras clave se recuperaron 74 trabajos, según los criterios de inclusión y objetivo del trabajo se revisaron 67 artículos. La aplicación de las plataformas de secuenciación en la investigación de casos de muerte súbita tomo auge en el 2014 y en poco tiempo, demostraron su versatilidad para el análisis de una gran cantidad de genes simultáneamente, de forma rápida y a bajo costo. Conclusiones: las patologías asociadas a muerte súbita son múltiples, complejas y pueden generar fenotipos variables que dificultan el análisis genético de las mismas. Las plataformas de secuenciación de siguiente generación son sumamente útiles en los casos de muerte súbita inexplicada, además permiten la identificación de variantes genéticas en familiares para la implementación de medidas preventivas...(AU)


Subject(s)
Humans , Autopsy/methods , Death, Sudden , Death, Sudden, Cardiac , High-Throughput Nucleotide Sequencing
10.
Arq. bras. oftalmol ; 86(5): e20230069, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1513687

ABSTRACT

ABSTRACT Purpose: The study aimed to evaluate the ocular surface and meibomian gland morphology in electronic cigarette (e-cigarette) smokers. Methods: The upper and lower eyelids of 25 male e-cigarette smokers and 25 healthy male non-smoker patients were evaluated using Sirius meibography. Meibomian glands loss was automatically calculated using Phoenix meibography imaging software module, with the result obtained as percentage loss. Ocular Surface Disease Index (OSDI) questionnaire, tear breakup time test, and Schirmer II test were administered and performed in all cases. Results: The mean e-cigarette smoking duration was 4.9 ± 0.9 (range, 3.4-7) years. While the mean Schirmer II test value was 9.16 ± 2.09 mm in e-cigarette group, it was 11.20 ± 2.14 mm in control group (p=0.003). Mean tear breakup time was 6.96 ± 2.31 seconds in e-cigarette group and 9.84 ± 2.13 seconds in control group (p=0.002). The mean OSDI value was 28.60 ± 6.54 and 15.16 ± 7.23 in e-cigarette and control groups, respectively (p<0.001). In Sirius meibography, the average loss for the upper eyelid was 23.08% ± 6.55% in e-cigarette group and 17.60% ± 4.94% in control group (p=0.002), and the average loss for the lower eyelid was 27.84% ± 5.98% and 18.44% ± 5.91%, respectively (p<0.001). Additionally, a significant positive correlation was identified between the loss rates for both upper and lower eyelid meibography with e-cigarette smoking duration (r=0.348, p<0.013 and r=0.550, p<0.001, respectively). Conclusion: Long-term e-cigarette smoking causes damage to the meibomian glands; therefore, meibomian gland damage should be considered in ocular surface disorders due to e-ci­garette smoking.


RESUMO Objetivo: Avaliar a superfície ocular e a morfologia da glândula meibomiana em usuários de cigarros eletrônicos. Métodos: Foram avaliadas através de meibografia Sirius as pálpebras superiores e inferiores de 25 usuários de cigarros eletrônicos do sexo masculino e 25 pacientes não usuários saudáveis, também do sexo masculino. A perda nas glândulas meibomianas foi calculada automaticamente com o módulo de software de imagem de meibografia Phoenix. O resultado foi obtido como perda percentual. O questionário Ocular Surface Disease Index (OSDI), o teste do tempo de ruptura lacrimal e o teste de Schirmer II foram administrados em todos os casos. Resultados: A duração média do uso de cigarros eletrônicos foi de 4,9 ± 0,9 anos (intervalo de 3,4-7 anos). O valor médio do teste de Schirmer II foi de 9,16 ± 2,09 mm no grupo de usuários de cigarros eletrônicos e de 11,20 ± 2,14 mm no grupo controle (p=0,003). O valor médio do teste do tempo de ruptura lacrimal foi de 6,96 ± 2,31 segundos no grupo de usuários de cigarros eletrônicos e 9,84 ± 2,13 segundos no grupo controle (p=0,002). O valor médio do Ocular Surface Disease Index foi de 28,60 ± 6,54 e 15,16 ± 7,23 para os grupos de usuários de cigarros eletrônicos e controle, respectivamente (p<0,001). Na meibografia de Sirius, a perda média para a pálpebra superior foi de 23,08 ± 6,55% para o grupo de usuários de cigarros eletrônicos e 17,60 ± 4,94% para o grupo controle (p=0,002), e a perda média para a pálpebra inferior foi de 27,84 ± 5,98% e 18,44 ± 5,91%, respectivamente (p<0,001). Além disso, foi observada uma correlação positiva significativa entre a taxa de perda na meibografia palpebral superior e inferior com a duração do tabagismo eletrônico, respectivamente de (r=0,348, p<0,013) e (r=0,550, p<0,001). Conclusão: O uso prolongado de cigarros eletrônicos causa danos às glândulas meibomianas. Portanto, esses danos devem ser considerados em distúrbios da superfície ocular devidos ao uso desses dispositivos.

11.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1533685

ABSTRACT

Introducción: En el tramo distal del conducto anal es normal la presencia de unas estructuras a modo de cojines, constituidas por tejido vascular, denominadas plexos hemorroidales. Objetivo: Comparar las técnicas quirúrgicas abiertas y cerrada en la enfermedad hemorroidal en la provincia Camagüey, en el periodo comprendido desde enero de 2021 a enero de 2023. Métodos: Se realizó un estudio observacional, analítico de corte transversal. El universo lo conformaron 135 pacientes que acudieron a consulta con el diagnóstico de enfermedad hemorroidal. Se le realizó un muestreo aleatorio simple, donde se tomaron 15 pacientes de cada uno de los grupos para conformar una muestra total de 45, cada grupo fue tratado con una técnica quirúrgica diferente. Resultados: En relación al sexo predominó el femenino, el tiempo quirúrgico fue dado a los 30 minutos en las técnicas abiertas. El dolor postoperatorio como complicación inmediata fue significativo con la utilización de la técnica abierta Whitehead clásico, no existieron complicaciones mediatas en el estudio; mientras que en las tardías la estenosis anal fue la que más se manifestó. Conclusiones: Existió predomino del sexo femenino, el tiempo de quirúrgico de mayor frecuencia fue de 30 minutos en los pacientes operados con la técnica abiertas, en la mayor parte de los pacientes se constató dolor excesivo como complicación inmediata con las técnicas de Milligan-Morgan y Whitehead clásico abiertas no así con la cerrada de Ferguson. La estenosis anal fue la complicación quirúrgica tardía más frecuente asociada a la técnica de Whitehead clásico.


Introduction: In the distal section of the anal canal, the presence of "cushion"-like structures, mainly made up of vascular tissue, called hemorrhoid plexuses. Objective: To compare the open and closed surgical techniques in hemorrhoid disease in Camagüey province, in the period from January 2021 to January 2023. Methods: An observational, analytical, cross-sectional study was carried out. The universe was made up of 135 patients who attended the consultation with the diagnosis of hemorrhoid disease. A simple random sampling was carried out, where 15 patients from each of the groups were taken to form a total sample of 45 patients, each group was treated with a surgical technique. Results: In relation to sex, the female sex predominated, the surgical time was given at 30 minutes in the open techniques. Postoperative pain as an immediate complication was significant with the use of the classic Whitehead open technique; there were no mediate complications in this study; while in the late ones, anal stenosis was the one that manifested itself the most. Conclusions: There was a predominance of the female sex, the most frequent surgical time was 30 minutes in patients operated with the open technique, in most patients excessive pain was found as an immediate complication with the Milligan-Morgan and classic Whitehead open techniques, but not so with the closed technique of Ferguson. Anal stenosis was the most frequent late surgical complication associated with the classic Whitehead technique.

12.
J. bras. pneumol ; 49(4): e20230097, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1506591

ABSTRACT

ABSTRACT Objective: To assess predictive factors for improved diagnostic accuracy with the use of radial-probe EBUS (RP-EBUS). Methods: This was a retrospective review of consecutive patients undergoing RP-EBUS between February of 2012 and January of 2020. Parameters including the presence of a bronchus sign on CT scans, the position of the radial EBUS probe, lesion size, lesion location, and lesion type were analyzed in relation to two defined outcomes (final diagnosis or no diagnosis). Univariate analysis was used in order to explore the individual effects of each parameter on diagnostic accuracy. Multivariate logistic regression was performed to identify significant predictors of diagnostic accuracy. Results: RP-EBUS was used for diagnostic purposes in 101 patients. The lesion was < 3 cm in size in 59 patients (58.4%) and predominantly solid in 60.3%. There was a positive correlation between radial EBUS probe position and diagnostic accuracy (p = 0.036), with 80.9% of the patients showing a bronchus sign on CT scans. Furthermore, 89% of the patients showed a bronchus sign on CT scans and a correlation with diagnostic accuracy (p = 0.030), with 65.8% of the lesions being located in the left/right upper lobe (p = 0.046). When the radial EBUS probe was within the target lesion, the diagnostic yield was = 80.8%. When the probe was adjacent to the lesion, the diagnostic yield was = 19.2%. A bronchus sign on CT scans was the only parameter that independently influenced diagnostic accuracy (adjusted OR, 3.20; 95% CI, 1.081-9.770; p = 0.036). Conclusions: A bronchus sign on CT scans is a powerful predictor of successful diagnosis by RP-EBUS.


RESUMO Objetivo: Avaliar fatores preditivos de maior precisão diagnóstica com EBUS com sonda radial. Métodos: Revisão retrospectiva de pacientes consecutivos submetidos a EBUS radial entre fevereiro de 2012 e janeiro de 2020. Parâmetros como a presença do sinal brônquico na TC, a posição da sonda radial de EBUS, o tamanho da lesão, a localização da lesão e o tipo de lesão foram analisados em relação a dois desfechos definidos (diagnóstico final ou sem diagnóstico). A análise univariada foi usada para explorar os efeitos individuais de cada parâmetro na precisão do diagnóstico. A regressão logística multivariada foi realizada para identificar preditores significativos de precisão diagnóstica. Resultados: O EBUS radial foi usado para fins diagnósticos em 101 pacientes. A lesão era < 3 cm em 59 pacientes (58,4%) e predominantemente sólida em 60,3%. Houve correlação positiva entre a posição da sonda radial de EBUS e a precisão do diagnóstico (p = 0,036), sendo que 80,9% dos pacientes apresentaram o sinal brônquico na TC. Além disso, 89% dos pacientes apresentaram o sinal brônquico na TC e correlação com a precisão do diagnóstico (p = 0,030), sendo que 65,8% das lesões localizavam-se no lobo superior esquerdo/direito (p = 0,046). Com a sonda radial de EBUS dentro da lesão-alvo, o rendimento diagnóstico foi de 80,8%. Com a sonda adjacente à lesão, o rendimento diagnóstico foi de 19,2%. O sinal brônquico na TC foi o único parâmetro que influenciou de forma independente a precisão do diagnóstico (OR ajustada = 3,20; IC95%: 1,081-9,770; p = 0,036). Conclusões: O sinal brônquico na TC é um poderoso preditor de diagnóstico bem-sucedido por meio de EBUS radial.

14.
Arq. bras. oftalmol ; 86(6): e2021, 2023. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1520196

ABSTRACT

ABSTRACT Purpose: The purpose of this study was to compare the white-to-white distance measurements of two devices (IOL Master 500 and Atlas corneal topographer) commonly used in clinical practice to determine if they were interchangeable. Providing information on instrument interchangeability could eliminate several unnecessary tests and consequently reduce the economic burden for the patient and society. Methods: In this prospective, comparative case series, the white-to-white distance was measured by independent examiners using the Atlas topographer (Carl Zeiss Meditec) and the IOL Master 500 (Carl Zeiss Meditec). One eye each of 184 patients was tested. Statistical analyses were performed using a paired t-test, Pearson correlation analysis, and Bland-Altman analysis to compare the measurement methods. Results: The mean white-to-white distance measurements with the Atlas topographer and the IOL Master 500 were 12.20 ± 0.44 mm and 12.12 ± 0.41 mm, respectively (p<0.001). The mean white-to-white difference between the two devices was 0.07 mm (95% confidence interval of mean difference: 0.04-0.11 mm). The Pearson correlation coefficient between the two devices was 0.85 (p<0.0001). The 95% limits of agreement between the two devices were -0.38 mm to 0.53 mm. Conclusions: The Atlas topographer and IOL Master 500 can be used interchangeably with respect to white-to-white distance measurements, as the range of differences is unlikely to affect clinical practice and decision making.


RESUMO Objetivo: O objetivo deste estudo é comparar as medições de diâmetro corneano de dois dispositivos normalmente utilizados na prática clínica (IOL Master 500 e Atlas topógrafo corneal) para ver se são permutáveis. O fornecimento de informações sobre a permutabilidade de instrumentos poderia eliminar vários testes desnecessários e, consequentemente, reduzir a carga econômica para o paciente e para a sociedade. Métodos: Nesta série de casos prospectivos e comparativos, a distância do diâmetro corneano foi medida por examinadores independentes utilizando o Topógrafo Atlas (Carl Zeiss Meditec) e o IOL Master 500 (Carl Zeiss Meditec), em um olho de 184 pacientes. A análise estatística foi realizada utilizando o teste t pareado, a correlação Pearson e a análise Bland-Altman para comparar os métodos de medição. Resultados: As medições médias da distância do diâmetro corneano com o topógrafo Atlas e o IOL Master 500 foram de 12,20 ± 0,44 mm e 12,12 ± 0,41 mm, respectivamente (p<0,001). A diferença média de WTW entre os dois dispositivos foi de 0,07 mm (intervalo de confiança de 95% da diferença média: 0,04 - 0,11 mm). O coeficiente de correlação Pearson entre os dois dispositivos foi de 0,85, p<0,0001. Os limites de concordância de 95% entre os dois dispositivos foram de -0,38 mm a 0,53 mm. Conclusões: O Atlas topographer e o IOL Master 500 podem ser utilizados permutavelmente em relação à medição do diâmetro corneano, uma vez que a gama de diferenças encontradas é pouco susceptível de afetar a prática clínica e a tomada de decisões.

15.
Arq. bras. oftalmol ; 86(6): e2021, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1520207

ABSTRACT

ABSTRACT Purpose: To examine the epidemiological characteristics of children undergoing cataract surgery at a referral center in Sao Paulo State, Brazil, as well as the facts surrounding treatment delays. Methods: In this transversal observational study, 240 operated eyes from 178 children undergoing cataract surgery were reviewed. The following aspects were analyzed: epidemiological and clinical characteristics, parental observations, red reflex test, operated eye, and age at cataract diagnosis and surgery. Results: The mean ages at the first visit and cataract surgery were 48.9 months (SD=50.0 months) and 64.5 months (SD= 55.4 months), respectively. The most critical sign adverted by parents was leukocoria. The red reflex test was performed on two-thirds of the children, with abnormal results in 28.0%. A family history of cataracts was evident in 30 (20,9%) children (n=144). Previous ocular surgery was found in 37 (16,6%) of the eyes (n=223), anterior segment disorders in 20 (9,0%) eyes (n=221), strabismus in 21 (9,5%) of the eyes (n=220), and nystagmus in 38 (24,4%) of the children (n=156). Conclusions: One of the causes for the delay in admission may have been the failure to complete the red reflex. In terms of etiology, heredity was the most crucial component. The presence of strabismus and nystagmus in many of these children points to late diagnosis. The most significant impediments to adequate cataract treatment in children were the lack of referral programs and children's specialized ophthalmologic centers, in addition to the restricted number of support professionals trained in the field and pediatric ophthalmology specialists.


RESUMO Objetivos: Rever características epidemiológicas de crianças submetidas a cirurgia de catarata, em centro de referência no estado de São Paulo, Brasil, e fatos associados a atrasos no tratamento. Métodos: Um total de 240 olhos submetidos a cirurgia de catarata, em 178 crianças, foram revisados neste estudo transversal observacional. Os seguintes aspectos foram analisados: características clínicas e epidemiológicas, sinais apontados pelos pais, teste do reflexo vermelho, olho operado e idade no diagnóstico e na cirurgia. Resultados: A média de idades na primeira visita e cirurgia de catarata foi de 48.9 meses (DP=50,0 meses) e 64.5 meses (DP=55.4 meses), respectivamente. O sinal mais importante apontado pelos pais foi a leucocoria. O teste do reflexo vermelho foi realizado em dois terços das crianças com resultados anormais em 28%. Histórico familiar de catarata foi evidente em 30 (20,9%) crianças (n=144). Os achados mais prevalentes em termos de histórico de problemas oculares foram: cirurgias oculares prévias em 37 (16,6%) olhos (n= 223), alterações do segmento anterior em 20 (9,0%) olhos (n=221), estrabismo em 21 (9,5%) olhos (n=220) e nistagmo em 38 (24,4%) crianças (n=156). Conclusões: Uma das causas para o atraso na admissão pode ter sido a falha em realizar o teste do reflexo vermelho, apesar de não ter sido possível verificar se todas as crianças foram submetidas ao exame. A hereditariedade foi o fator mais importante quanto à causa da catarata nessas crianças. A presença de estrabismo e nistagmo mais uma vez aponta para o diagnóstico tardio. Ausência de programas de referência e centros oftalmológicos especializados em crianças, além do número restrito de profissionais de apoio treinados na área e especialistas em oftalmologia pediátrica, foram as barreiras mais importantes para o tratamento adequado da catarata em crianças.

16.
Biomédica (Bogotá) ; 42(supl.2): 59-72, oct. 2022. tab, graf
Article in Spanish | LILACS | ID: biblio-1403613

ABSTRACT

Introducción. Desde el primer reporte en la provincia de Wuhan (China) en el año 2019, el SARS-CoV-2 se ha diseminado por todo el mundo, provocando un enorme impacto en la salud pública. Para su diagnóstico, la Organización Mundial de la Salud ha incentivado el desarrollo de pruebas rápidas, de simple ejecución, sensibles y específicas, que complementan la RT-qPCR como prueba de referencia. La prueba RT-LAMP ha mostrado ser una excelente alternativa para la detección del SARS-CoV-2 en diferentes biofluidos. Objetivo. Validar la técnica RT-LAMP colorimétrica en muestras de hisopado nasofaríngeo previamente confirmadas por RT-qPCR, usando el protocolo Charité, Berlín, Alemania. Materiales y métodos. Un total de 153 muestras de hisopado nasofaríngeo de individuos con sospecha de COVID-19 se sometieron a RT-qPCR y RT-LAMP, usando un estuche comercial colorimétrico (NEB, Germany). La RT-LAMP se practicó con las muestras de ARN extraídas del hisopado nasofaríngeo y con muestras crudas sin previa extracción de ARN. El resultado fue evaluado por un simple cambio de color en la reacción. Resultados. La sensibilidad y especificidad de la técnica RT-LAMP para detectar el gen N del SARS-CoV-2 mediante un set de cebadores previamente reportados (set de Broughton), arrojó valores de 0,97 (0,85-1,00) y 0,81 (0,65-0,92), respectivamente, con un intervalo de confianza del 95%. Otro set de cebadores dirigidos contra otra región del mismo gen (set de Lalli) arrojó valores de sensibilidad y especificidad de 0,96 (0,78-1,00) y 0,77 (0,55-0,92), respectivamente. Sin previa extracción de ARN, se encontró que la sensibilidad fue del 0,95 (0,74-1,00) y la especificidad del 0,88 (0,64-0,99). Conclusiones. Estos resultados evidencian que la técnica RT-LAMP podría considerarse una prueba diagnóstica rápida, de fácil ejecución, libre de equipos sofisticados, sensible y específica, para el diagnóstico del SARS-CoV-2 en muestras de hisopados nasofaríngeos.


Introduction: Since the first report in Wuhan (China) in 2019, the SARS-CoV-2 virus has spread throughout the world, with a significant impact in public health. To contain its transmission, the WHO has encouraged the development of rapid, simple, sensitive and specific tests that complement qRT-PCR, as the gold standard. RT-LAMP has shown to be a good alternative to detect SARS-CoV-2 in different fluid samples. Objective: To validate the colorimetric RT-LAMP technique using two sets of primers targeting N gene of SARS-CoV-2 in 117 nasopharyngeal swab samples previously confirmed by RT-qPCR, using the Charité/Berlin protocol. Material and methods: A total of 153 nasopharyngeal swab samples from individuals with suspected COVID-19 were subjected to qRT-PCR and RT-LAMP using a commercial colorimetric kit (NEB, Germany). RT-LAMP was performed using both extracted RNA samples and raw samples without prior RNA extraction, and the result was assessed by a simple color change in the reaction. Results: Sensitivity and specificity for the previously reported RT-LAMP primers (Broughton set) targeting N gene of SARS-CoV-2 were 0.97 (0.85-1.00) and 0.81 (0.65-0.92) respectively, with CI95%. The Lalli primers targeting another region of the N gene used showed a sensitivity value of 0.96 (0.78-1.00) and a specificity of 0.77 (0.55-0.92). Without RNA extraction we found a sensitivity value of 0.95 (0.74, 1.00) and a specificity of 0.88 (0.64, 0.99). A sensitivity value of 0.95 (0.74-1.00) and a specificity 0.88 (0.64-0.99) were found without prior RNA extraction. Conclusion: Taking together, the results showed that RT-LAMP technique could be considered as a rapid diagnostic test, easy to perform, free of sophisticated equipment, sensitive and specific to diagnose SARS-CoV-2 in nasopharyngeal swabs with and without prior RNA extraction, allowing its implementation in places with scarce resources.


Subject(s)
Molecular Diagnostic Techniques , COVID-19/diagnosis , Sensitivity and Specificity , Point-of-Care Testing
17.
Acta med. peru ; 39(4)oct. 2022.
Article in English | LILACS-Express | LILACS | ID: biblio-1419911

ABSTRACT

Objective: To compare the isothermal molecular screening techniques CPA and RT-LAMP, against the gold standard test, reverse transcription quantitative polymerase chain reaction (RT-qPCR), and to determine its agreement. Materials and Methods: Paired comparative case-control study. For the evaluation of the CPA method, 70 cases and 130 controls were used, while for RT-LAMP, 30 cases and 70 controls were used. The sensitivity and specificity of both tests were calculated. Subsequently, the bias-corrected Kappa index was calculated by resampling. Results: Both techniques have adequate and equivalent values of sensitivity (RT-LAMP: 82.8%, CPA: 83%) and specificity (RT-LAMP and CPA: 91.5%), as well as a high concordance (88%), and Kappa-index (0.72). Conclusion: Both isothermal molecular screening techniques are suitable for SARS-CoV-2 screening, with a similar sensitivity and specificity.


Objetivo : Comparar las técnicas de cribado molecular isotérmico CPA y RT-LAMP, frente a la prueba de referencia, la reacción en cadena de la polimerasa cuantitativa de transcripción inversa (RT-qPCR), y determinar su concordancia. Materiales y métodos : Estudio comparativo de casos y controles emparejados. Para la evaluación del método CPA se utilizaron 70 casos y 130 controles, mientras que para la RT-LAMP se utilizaron 30 casos y 70 controles. Se calcularon la sensibilidad y la especificidad de ambas pruebas. Posteriormente, se calculó el índice Kappa corregido por sesgo mediante un nuevo muestreo. Resultados: Ambas técnicas presentan valores adecuados y equivalentes de sensibilidad (RT-LAMP: 82,8 %, CPA: 83 %) y especificidad (RT-LAMP y CPA: 91,5 %), así como una alta concordancia (88 %), y un índice Kappa (0,72). Conclusiones: Ambas técnicas de cribado molecular isotérmico son adecuadas para el cribado del SARS-CoV-2, con una sensibilidad y especificidad similares.

18.
Arq. bras. cardiol ; 119(3): 468-469, set. 2022.
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1403346
19.
Rev. peru. med. exp. salud publica ; 39(3): 312-320, jul.-sep. 2022. tab, graf
Article in Spanish | LILACS | ID: biblio-1410010

ABSTRACT

RESUMEN Objetivo. Desarrollar y evaluar un método de bajo costo basado en celulosa para la purificación rápida y amplificación directa de ADN de Bordetella pertussis de hisopados nasofaríngeos. Materiales y métodos. Se prepararon discos de celulosa y se evaluaron diferentes parámetros (buffers de lisis/lavado, número de discos y elución de ADN). El método se acopló a una amplificación directa por PCR en tiempo real (qPCR) y se estimó el rendimiento utilizando hisopados nasofaríngeos que fueron positivos (n=100) y negativos (n=50) para ADN B. pertussis por qPCR, comparado con el método basado en columnas de sílice. Se calculó el grado de concordancia, sensibilidad, especificidad, valor predictivo positivo (VPP) y valor predictivo negativo (VPN). Se evaluó la factibilidad del método rápido para ser acoplado a un ensayo colorimétrico de amplificación isotérmica mediada por lazo (LAMP). Resultados. El método rápido con un disco de celulosa y buffer de lisis y lavado conteniendo PVP-40 y Tween 20, respectivamente, mostró una mayor capacidad para purificar ADN amplificable de B. pertussis. El método tuvo una sensibilidad de 89,0% (IC95%, 80,2%-94,9%) y una especificidad de 98,5% (IC95%, 92,1%-100,0%), con un buen grado de concordancia (Kappa=0,867; IC95% 0,788 - 0,946), respecto al método referencial. Los VPP y VPN fueron 98,6% (IC95%, 92,7,2%-100,0%) y 88,2% (IC95%, 78,7%-94,4%), respectivamente. Se evidenció una amplificación exitosa por LAMP, y se obtuvieron resultados comparables con el método por columnas de sílice. Conclusión. El método desarrollado es simple, de bajo costo y libre de equipos para la obtención rápida (60 segundos) de ADN en el punto de atención, y puede ser implementado en diversas técnicas moleculares orientados al diagnóstico oportuno y al estudio epidemiológico de tos ferina.


ABSTRACT Objective. To develop and evaluate a low-cost cellulose-based method for rapid purification and direct amplification of Bordetella pertussis DNA from nasopharyngeal swabs. Materials and methods. We prepared cellulose discs and evaluated different parameters (lysis/wash buffers, number of discs and DNA elution). The method was coupled to a direct real-time PCR (qPCR) amplification and the performance was estimated using nasopharyngeal swabs that were positive (n=100) and negative (n=50) for B. pertussis DNA by qPCR, compared to the silica column-based method. We calculated sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) and the degree of agreement. The feasibility of the rapid method to be coupled to a loop-mediated isothermal amplification colorimetric assay (LAMP) was evaluated. Results. The rapid method, with a cellulose disk and lysis and wash buffer containing PVP-40 and Tween 20, respectively, showed a greater capacity to purify amplifiable DNA from B. pertussis. The method had a sensitivity of 89.0% (95%CI: 80.2%-94.9%) and a specificity of 98.5% (95%CI: 92.1%-100.0%), with a good degree of agreement (Kappa=0.867; 95%CI: 0.788 - 0.946), compared to the reference method. The PPV and NPV were 98.6% (95%CI: 92.7.2%-100.0%) and 88.2% (95%CI: 78.7%-94.4%), respectively. Successful amplification by LAMP was evident, and comparable results were obtained with the silica column method. Conclusion. The developed method is simple, low-cost and equipment-free for rapid (60 seconds) DNA collection at the point of care, and can be implemented in various molecular techniques aimed at the timely diagnosis and epidemiological study of pertussis.


Subject(s)
Humans , Bordetella pertussis/genetics , DNA, Bacterial/isolation & purification , Cellulose , Real-Time Polymerase Chain Reaction , Whooping Cough/diagnosis , Nasopharynx/microbiology , Sensitivity and Specificity , Molecular Diagnostic Techniques
20.
Rev. méd. Paraná ; 80(1): 1-2, jan. 2022.
Article in Portuguese | LILACS | ID: biblio-1381074

ABSTRACT

A tomografia computadorizada (TC) é exame de escolha para rastreamento de lesões no traumatismo cranioencefálico (TCE). Apesar disso, seu uso rotineiro no TCE leve é controverso O objetivo desta revisão foi avaliar o impacto da aplicação de diretrizes de manejo e conduta de TCE leve quanto à solicitação de TC de crânio. É busca realizada nas bases de dados LILACS, Medline, PubMed, SciELO, utilizando descritores do MeSH e DeCS. A busca inicial identificou 30.191 artigos. Após remoção de publicações duplicadas, seleção pelo título, seleção pelo resumo, restaram 25 publicações, que foram lidas na íntegra e cinco incluídas na presente revisão sistemática. Em conclusão, os artigos analisados apresentaram, em média, redução de 25,8% na solicitação de TC de crânio quando aplicadas as diretrizes, e orientam que protocolos para TCE leve são ferramentas eficientes para auxiliar a prática médica, impactando positivamente quando aplicados na população, devendo sempre ser levado em conta a avaliação clínica.


Computed tomography (CT) is the exam of choice for tracking injuries in traumatic brain injury (TBI). Despite this, its routine use in mild TBI is controversial. The objective of this review was to evaluate the impact of applying guidelines for the management and conduct of mild TBI on the request for CT of the head. A search was carried out in the LILACS, Medline, PubMed, SciELO databases, using MeSH and DeCS descriptors. The initial search identified 30,191 articles. After removal of duplicate publications, selection by title, selection by abstract, 25 publications remained, which were read in full and five were included in this systematic review. In conclusion, the articles analyzed showed, on average, a 25.8% reduction in the request for cranial CT when the guidelines were applied, and guide that protocols for mild TBI are efficient tools to assist medical practice, positively impacting when applied to the population. , and clinical evaluation should always be taken into account.


Subject(s)
Humans , Tomography, X-Ray Computed , Diagnostic Techniques, Neurological , Craniocerebral Trauma , Skull , Brain Injuries, Traumatic
SELECTION OF CITATIONS
SEARCH DETAIL